Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 394
Filtrar
1.
JMIR Cardio ; 8: e54801, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38587880

RESUMO

BACKGROUND: Short-term blood pressure variability (BPV) is associated with arterial stiffness in patients with hypertension. Few studies have examined associations between arterial stiffness and digital home BPV over a mid- to long-term time span, irrespective of underlying hypertension. OBJECTIVE: This study aims to investigate if arterial stiffness traits were associated with subsequent mid- to long-term home BPV in the electronic Framingham Heart Study (eFHS). We hypothesized that higher arterial stiffness was associated with higher home BPV over up to 1-year follow-up. METHODS: At a Framingham Heart Study research examination (2016-2019), participants underwent arterial tonometry to acquire measures of arterial stiffness (carotid-femoral pulse wave velocity [CFPWV]; forward pressure wave amplitude [FWA]) and wave reflection (reflection coefficient [RC]). Participants who agreed to enroll in eFHS were provided with a digital blood pressure (BP) cuff to measure home BP weekly over up to 1-year follow-up. Participants with less than 3 weeks of BP readings were excluded. Linear regression models were used to examine associations of arterial measures with average real variability (ARV) of week-to-week home systolic (SBP) and diastolic (DBP) BP adjusting for important covariates. We obtained ARV as an average of the absolute differences of consecutive home BP measurements. ARV considers not only the dispersion of the BP readings around the mean but also the order of BP readings. In addition, ARV is more sensitive to measurement-to-measurement BPV compared with traditional BPV measures. RESULTS: Among 857 eFHS participants (mean age 54, SD 9 years; 508/857, 59% women; mean SBP/DBP 119/76 mm Hg; 405/857, 47% hypertension), 1 SD increment in FWA was associated with 0.16 (95% CI 0.09-0.23) SD increments in ARV of home SBP and 0.08 (95% CI 0.01-0.15) SD increments in ARV of home DBP; 1 SD increment in RC was associated with 0.14 (95% CI 0.07-0.22) SD increments in ARV of home SBP and 0.11 (95% CI 0.04-0.19) SD increments in ARV of home DBP. After adjusting for important covariates, there was no significant association between CFPWV and ARV of home SBP, and similarly, no significant association existed between CFPWV and ARV of home DBP (P>.05). CONCLUSIONS: In eFHS, higher FWA and RC were associated with higher mid- to long-term ARV of week-to-week home SBP and DBP over 1-year follow-up in individuals across the BP spectrum. Our findings suggest that higher aortic stiffness and wave reflection are associated with higher week-to-week variation of BP in a home-based setting over a mid- to long-term time span.

2.
PLoS One ; 19(3): e0299516, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38457401

RESUMO

Point-of-care technology (POCT) plays a vital role in modern healthcare by providing a fast diagnosis, improving patient management, and extending healthcare access to remote and resource-limited areas. The objective of this study was to understand how healthcare professionals in the United States perceived POCTs during 2019-2021 to assess the decision-making process of implementing these newer technologies into everyday practice. A 5-point Likert scale survey was sent to respondents to evaluate their perceptions of benefits, concerns, characteristics, and development of point-of-care technologies. The 2021 survey was distributed November 1st, 2021- February 15th, 2022, with a total of 168 independent survey responses received. Of the respondents, 59% identified as male, 73% were white, and 48% have been in practice for over 20 years. The results showed that most agreed that POCTs improve patient management (94%) and improve clinician confidence in decision making (92%). Healthcare professionals were most concerned with potentially not being reimbursed for the cost of the POCT (37%). When asked to rank the top 3 important characteristics of POCT, respondents chose accuracy, ease of use, and availability. It is important to note this survey was conducted during the COVID-19 pandemic. To achieve an even greater representation of healthcare professionals' point of view on POCTs, further work to obtain responses from a larger, more diverse population of providers is needed.


Assuntos
Pandemias , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Masculino , Pessoal de Saúde , Atenção à Saúde , Inquéritos e Questionários
4.
J Virol ; 98(1): e0161823, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38174928

RESUMO

The global evolution of SARS-CoV-2 depends in part upon the evolutionary dynamics within individual hosts with varying immune histories. To characterize the within-host evolution of acute SARS-CoV-2 infection, we sequenced saliva and nasal samples collected daily from vaccinated and unvaccinated individuals early during infection. We show that longitudinal sampling facilitates high-confidence genetic variant detection and reveals evolutionary dynamics missed by less-frequent sampling strategies. Within-host dynamics in both unvaccinated and vaccinated individuals appeared largely stochastic; however, in rare cases, minor genetic variants emerged to frequencies sufficient for forward transmission. Finally, we detected significant genetic compartmentalization of viral variants between saliva and nasal swab sample sites in many individuals. Altogether, these data provide a high-resolution profile of within-host SARS-CoV-2 evolutionary dynamics.IMPORTANCEWe detail the within-host evolutionary dynamics of SARS-CoV-2 during acute infection in 31 individuals using daily longitudinal sampling. We characterized patterns of mutational accumulation for unvaccinated and vaccinated individuals, and observed that temporal variant dynamics in both groups were largely stochastic. Comparison of paired nasal and saliva samples also revealed significant genetic compartmentalization between tissue environments in multiple individuals. Our results demonstrate how selection, genetic drift, and spatial compartmentalization all play important roles in shaping the within-host evolution of SARS-CoV-2 populations during acute infection.


Assuntos
Evolução Molecular , Deriva Genética , SARS-CoV-2 , Humanos , COVID-19/virologia , Nariz/virologia , Saliva/virologia , SARS-CoV-2/genética , Masculino , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade
5.
IEEE Trans Biomed Eng ; 71(2): 456-466, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37682653

RESUMO

OBJECTIVE: We propose an efficient approach based on a convolutional denoising autoencoder (CDA) network to reduce motion and noise artifacts (MNA) from corrupted atrial fibrillation (AF) and non-AF photoplethysmography (PPG) data segments so that an accurate PPG-signal-derived heart rate can be obtained. Our method's main innovation is the optimization of the CDA performance for both rhythms using more AF than non-AF data for training the AF-specific CDA model and vice versa for the non-AF CDA network. METHODS: To evaluate this unconventional training scheme, our proposed network was trained and tested on 25-sec PPG data segments from 48 subjects from two different databases-the Pulsewatch dataset and Stanford University's publicly available PPG dataset. In total, our dataset contains 10,773 data segments: 7,001 segments for training and 3,772 independent segments from out-of-sample subjects for testing. RESULTS: Using real-life corrupted PPG segments, our approach significantly reduced the average heart rate root mean square error (RMSE) of the reconstructed PPG segments by 45.74% and 23% compared to the corrupted non-AF and AF data, respectively. Further, our approach exhibited lower RMSE, and higher sensitivity and PPV for detected peaks compared to the reconstructed data produced by the alternative methods. CONCLUSION: These results show the promise of our approach as a reliable denoising method, which should be used prior to AF detection algorithms for an accurate cardiac health monitoring involving wearable devices. SIGNIFICANCE: PPG signals collected from wearables are vulnerable to MNA, which limits their use as a reliable measurement, particularly in uncontrolled real-life environments.


Assuntos
Fibrilação Atrial , Fotopletismografia , Humanos , Fotopletismografia/métodos , Fibrilação Atrial/diagnóstico , Frequência Cardíaca/fisiologia , Monitorização Fisiológica , Movimento (Física) , Algoritmos , Processamento de Sinais Assistido por Computador , Artefatos
6.
J Am Heart Assoc ; 13(1): e032126, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38156452

RESUMO

BACKGROUND: Consumer wearable devices with health and wellness features are increasingly common and may enhance disease detection and management. Yet studies informing relationships between wearable device use, attitudes toward device data, and comprehensive clinical profiles are lacking. METHODS AND RESULTS: WATCH-IT (Wearable Activity Tracking for Comprehensive Healthcare-Integrated Technology) studied adults receiving longitudinal primary or ambulatory cardiovascular care in the Mass General Brigham health care system from January 2010 to July 2021. Participants completed a 20-question electronic survey about perceptions and use of consumer wearable devices, with responses linked to electronic health records. Multivariable logistic regression was used to identify factors associated with device use. Among 214 992 individuals receiving longitudinal primary or cardiovascular care with an active electronic portal, 11 121 responded (5.2%). Most respondents (55.8%) currently used a wearable device, and most nonusers (95.3%) would use a wearable if provided at no cost. Although most users (70.2%) had not shared device data with their doctor previously, most believed it would be very (20.4%) or moderately (34.4%) important to share device-related health information with providers. In multivariable models, older age (odds ratio [OR], 0.80 per 10-year increase [95% CI, 0.77-0.82]), male sex (OR, 0.87 [95% CI, 0.80-0.95]), and heart failure (OR, 0.75 [95% CI, 0.63-0.89]) were associated with lower odds of wearable device use, whereas higher median income (OR, 1.08 per 1-quartile increase [95% CI, 1.04-1.12]) and care in a cardiovascular medicine clinic (OR, 1.17 [95% CI, 1.05-1.30]) were associated with greater odds of device use. CONCLUSIONS: Among patients in primary and cardiovascular medicine clinics, consumer wearable device use is common, and most users perceive value in wearable health data.


Assuntos
Dispositivos Eletrônicos Vestíveis , Adulto , Humanos , Masculino , Inquéritos e Questionários , Registros Eletrônicos de Saúde , Atitude , Atenção à Saúde
7.
medRxiv ; 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-38045229

RESUMO

Objectives: To examine the associations between catheter ablation treatment (CA) versus medical management and cognitive impairment among older adults with atrial fibrillation (AF). Methods: Ambulatory patients who had AF, were ≥ 65-years-old, and were eligible to receive oral anticoagulation could be enrolled into the SAGE (Systematic Assessment of Geriatric Elements)-AF study from internal medicine and cardiology clinics in Massachusetts and Georgia between 2016 and 2018. Cognitive function was assessed using the Montreal Cognitive Assessment (MoCA) tool at baseline, one-, and two years. Cognitive impairment was defined as a MoCA score ≤ 23. Multivariate-adjusted logistic regression of longitudinal repeated measures was used to examine associations between treatment with CA vs. medical management and cognitive impairment. Results: 887 participants were included in this analysis. On average, participants were 75.2 ± 6.7 years old, 48.6% women, and 87.4% white non-Hispanic. 193 (21.8%) participants received a CA before enrollment. Participants who had previously undergone CA were significantly less likely to be cognitively impaired during the two-year study period (aOR 0.70, 95% CI 0.50-0.97) than those medically managed (i.e., rate and/or rhythm control), even after adjusting with propensity score for CA. At the two-year follow-up a significantly greater number of individuals in the non-CA group were cognitively impaired (MoCA ≤ 23) compared to the CA-group (311 [44.8%] vs. 58 [30.1%], p=0.0002). Conclusions: In this two-year longitudinal prospective cohort study participants who underwent CA for AF before enrollment were less likely to have cognitive impairment than those who had not undergone CA.

8.
Front Digit Health ; 5: 1243959, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38125757

RESUMO

Background: Increasing ownership of smartphones among Americans provides an opportunity to use these technologies to manage medical conditions. We examine the influence of baseline smartwatch ownership on changes in self-reported anxiety, patient engagement, and health-related quality of life when prescribed smartwatch for AF detection. Method: We performed a post-hoc secondary analysis of the Pulsewatch study (NCT03761394), a clinical trial in which 120 participants were randomized to receive a smartwatch-smartphone app dyad and ECG patch monitor compared to an ECG patch monitor alone to establish the accuracy of the smartwatch-smartphone app dyad for detection of AF. At baseline, 14 days, and 44 days, participants completed the Generalized Anxiety Disorder-7 survey, the Health Survey SF-12, and the Consumer Health Activation Index. Mixed-effects linear regression models using repeated measures with anxiety, patient activation, physical and mental health status as outcomes were used to examine their association with smartwatch ownership at baseline. Results: Ninety-six participants, primarily White with high income and tertiary education, were randomized to receive a study smartwatch-smartphone dyad. Twenty-four (25%) participants previously owned a smartwatch. Compared to those who did not previously own a smartwatch, smartwatch owners reported significant greater increase in their self-reported physical health (ß = 5.07, P < 0.05), no differences in anxiety (ß = 0.92, P = 0.33), mental health (ß = -2.42, P = 0.16), or patient activation (ß = 1.86, P = 0.54). Conclusions: Participants who own a smartwatch at baseline reported a greater positive change in self-reported physical health, but not in anxiety, patient activation, or self-reported mental health over the study period.

9.
Clin Infect Dis ; 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37972270

RESUMO

BACKGROUND: There is evidence of an association of severe COVID-19 outcomes with increased body mass index (BMI) and male sex. However, few studies have examined the interaction between sex and BMI on SARS-CoV-2 viral dynamics. METHODS: Participants conducted RT-PCR testing every 24-48 hours over a 15-day period. Sex and BMI were self-reported, and Ct values from E-gene were used to quantify viral load. Three distinct outcomes were examined using mixed effects generalized linear models, linear models, and logistic models, respectively: all Ct values (Model 1); nadir Ct value (model 2); and strongly detectable infection (at least one Ct value ≤28 during their infection) (Model 3). An interaction term between BMI and sex was included, and inverse logit transformations were applied to quantify the differences by BMI and sex using marginal predictions. RESULTS: In total, 7,988 participants enrolled in this study, and 439 participants (Model 1) and 309 (Model 2 and 3) were eligible for these analyses. Among males, increasing BMI was associated with lower Ct values in a dose-response fashion. For participants with BMIs greater than 29, males had significantly lower Ct values and nadir Ct values than females. In total, 67.8% of males and 55.3% of females recorded a strongly detectable infection; increasing proportions of men had Ct values <28 with BMIs of 35 and 40. CONCLUSIONS: We observed sex-based dimorphism in relation to BMI and COVID-19 viral load. Further investigation is needed to determine the cause, clinical impact, and transmission implications of this sex-differential effect of BMI on viral load.

10.
JMIR Cardio ; 7: e45137, 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38015598

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a common cause of stroke, and timely diagnosis is critical for secondary prevention. Little is known about smartwatches for AF detection among stroke survivors. We aimed to examine accuracy, usability, and adherence to a smartwatch-based AF monitoring system designed by older stroke survivors and their caregivers. OBJECTIVE: This study aims to examine the feasibility of smartwatches for AF detection in older stroke survivors. METHODS: Pulsewatch is a randomized controlled trial (RCT) in which stroke survivors received either a smartwatch-smartphone dyad for AF detection (Pulsewatch system) plus an electrocardiogram patch or the patch alone for 14 days to assess the accuracy and usability of the system (phase 1). Participants were subsequently rerandomized to potentially 30 additional days of system use to examine adherence to watch wear (phase 2). Participants were aged 50 years or older, had survived an ischemic stroke, and had no major contraindications to oral anticoagulants. The accuracy for AF detection was determined by comparing it to cardiologist-overread electrocardiogram patch, and the usability was assessed with the System Usability Scale (SUS). Adherence was operationalized as daily watch wear time over the 30-day monitoring period. RESULTS: A total of 120 participants were enrolled (mean age 65 years; 50/120, 41% female; 106/120, 88% White). The Pulsewatch system demonstrated 92.9% (95% CI 85.3%-97.4%) accuracy for AF detection. Mean usability score was 65 out of 100, and on average, participants wore the watch for 21.2 (SD 8.3) of the 30 days. CONCLUSIONS: Our findings demonstrate that a smartwatch system designed by and for stroke survivors is a viable option for long-term arrhythmia detection among older adults at risk for AF, though it may benefit from strategies to enhance adherence to watch wear. TRIAL REGISTRATION: ClinicalTrials.gov NCT03761394; https://clinicaltrials.gov/study/NCT03761394. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1016/j.cvdhj.2021.07.002.

11.
J Gen Intern Med ; 38(16): 3526-3534, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37758967

RESUMO

BACKGROUND: Anticoagulants including direct oral anticoagulants (DOACs) are among the highest-risk medications in the United States. We postulated that routine consultation and follow-up from a clinical pharmacist would reduce clinically important medication errors (CIMEs) among patients beginning or resuming a DOAC in the ambulatory care setting. OBJECTIVE: To evaluate the effectiveness of a multicomponent intervention for reducing CIMEs. DESIGN: Randomized controlled trial. PARTICIPANTS: Ambulatory patients initiating a DOAC or resuming one after a complication. INTERVENTION: Pharmacist evaluation and monitoring based on the implementation of a recently published checklist. Key elements included evaluation of the appropriateness of DOAC, need for DOAC affordability assistance, three pharmacist-initiated telephone consultations, access to a DOAC hotline, documented hand-off to the patient's continuity provider, and monitoring of follow-up laboratory tests. CONTROL: Coupons and assistance to increase the affordability of DOACs. MAIN MEASURE: Anticoagulant-related CIMEs (Anticoagulant-CIMEs) and non-anticoagulant-related CIMEs over 90 days from DOAC initiation; CIMEs identified through masked assessment process including two physician adjudication of events presented by a pharmacist distinct from intervention pharmacist who reviewed participant electronic medical records and interview data. ANALYSIS: Incidence and incidence rate ratio (IRR) of CIMEs (intervention vs. control) using multivariable Poisson regression modeling. KEY RESULTS: A total of 561 patients (281 intervention and 280 control patients) contributed 479 anticoagulant-CIMEs including 31 preventable and ameliorable ADEs and 448 significant anticoagulant medication errors without subsequent documented ADEs (0.95 per 100 person-days). Failure to perform required blood tests and concurrent, inappropriate usage of a DOAC with aspirin or NSAIDs were the most common anticoagulant-related CIMEs despite pharmacist documentation systematically identifying these issues when present. There was no reduction in anticoagulant-related CIMEs among intervention patients (IRR 1.17; 95% CI 0.98-1.42) or non-anticoagulant-related CIMEs (IRR 1.05; 95% CI 0.80-1.37). CONCLUSION: A multi-component intervention in which clinical pharmacists implemented an evidence-based DOAC Checklist did not reduce CIMEs. NIH TRIAL NUMBER: NCT04068727.


Assuntos
Anticoagulantes , Farmacêuticos , Humanos , Anticoagulantes/efeitos adversos , Erros de Medicação , Assistência Ambulatorial , Registros Eletrônicos de Saúde , Administração Oral
12.
BMC Public Health ; 23(1): 1848, 2023 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-37735647

RESUMO

BACKGROUND: Many interventions for widescale distribution of rapid antigen tests for COVID-19 have utilized online, direct-to-consumer (DTC) ordering systems; however, little is known about the sociodemographic characteristics of home-test users. We aimed to characterize the patterns of online orders for rapid antigen tests and determine geospatial and temporal associations with neighborhood characteristics and community incidence of COVID-19, respectively. METHODS: This observational study analyzed online, DTC orders for rapid antigen test kits from beneficiaries of the Say Yes! Covid Test program from March to November 2021 in five communities: Louisville, Kentucky; Indianapolis, Indiana; Fulton County, Georgia; O'ahu, Hawaii; and Ann Arbor/Ypsilanti, Michigan. Using spatial autoregressive models, we assessed the geospatial associations of test kit distribution with Census block-level education, income, age, population density, and racial distribution and Census tract-level Social Vulnerability Index. Lag association analyses were used to measure the association between online rapid antigen kit orders and community-level COVID-19 incidence. RESULTS: In total, 164,402 DTC test kits were ordered during the intervention. Distribution of tests at all sites were significantly geospatially clustered at the block-group level (Moran's I: p < 0.001); however, education, income, age, population density, race, and social vulnerability index were inconsistently associated with test orders across sites. In Michigan, Georgia, and Kentucky, there were strong associations between same-day COVID-19 incidence and test kit orders (Michigan: r = 0.89, Georgia: r = 0.85, Kentucky: r = 0.75). The incidence of COVID-19 during the current day and the previous 6-days increased current DTC orders by 9.0 (95% CI = 1.7, 16.3), 3.0 (95% CI = 1.3, 4.6), and 6.8 (95% CI = 3.4, 10.2) in Michigan, Georgia, and Kentucky, respectively. There was no same-day or 6-day lagged correlation between test kit orders and COVID-19 incidence in Indiana. CONCLUSIONS: Our findings suggest that online ordering is not associated with geospatial clustering based on sociodemographic characteristics. Observed temporal preferences for DTC ordering can guide public health messaging around DTC testing programs.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , COVID-19/epidemiologia , Fatores Sociodemográficos , Escolaridade , Censos , Análise por Conglomerados
13.
Cardiovasc Digit Health J ; 4(4): 118-125, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37600446

RESUMO

Background: The detection of atrial fibrillation (AF) in stroke survivors is critical to decreasing the risk of recurrent stroke. Smartwatches have emerged as a convenient and accurate means of AF diagnosis; however, the impact on critical patient-reported outcomes, including anxiety, engagement, and quality of life, remains ill defined. Objectives: To examine the association between smartwatch prescription for AF detection and the patient-reported outcomes of anxiety, patient activation, and self-reported health. Methods: We used data from the Pulsewatch trial, a 2-phase randomized controlled trial that included participants aged 50 years or older with a history of ischemic stroke. Participants were randomized to use either a proprietary smartphone-smartwatch app for 30 days of AF monitoring or no cardiac rhythm monitoring. Validated surveys were deployed before and after the 30-day study period to assess anxiety, patient activation, and self-rated physical and mental health. Logistic regression and generalized estimation equations were used to examine the association between smartwatch prescription for AF monitoring and changes in the patient-reported outcomes. Results: A total of 110 participants (mean age 64 years, 41% female, 91% non-Hispanic White) were studied. Seventy percent of intervention participants were novice smartwatch users, as opposed to 84% of controls, and there was no significant difference in baseline rates of anxiety, activation, or self-rated health between the 2 groups. The incidence of new AF among smartwatch users was 6%. Participants who were prescribed smartwatches did not have a statistically significant change in anxiety, activation, or self-reported health as compared to those who were not prescribed smartwatches. The results held even after removing participants who received an AF alert on the watch. Conclusion: The prescription of smartwatches to stroke survivors for AF monitoring does not adversely affect key patient-reported outcomes. Further research is needed to better inform the successful deployment of smartwatches in clinical practice.

14.
Heart Rhythm O2 ; 4(8): 469-477, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37645259

RESUMO

Background: Despite benefits of oral anticoagulation (OAC), many individuals with diagnosed atrial fibrillation (AF) do not receive OAC. Objective: The purpose of this study was to assess whether cardiac rhythm assessment for AF impacted use of OAC in patients with previously diagnosed AF. Methods: VITAL-AF was a cluster randomized controlled trial conducted in 16 primary care practices assessing the efficacy of AF rhythm assessment with single-lead electrocardiogram in routine care. Patients 65 years and older were offered rhythm assessment at visits. In this secondary analysis, we evaluated rhythm assessment uptake and compared initiation and discontinuation of OAC in patients with previously diagnosed AF from intervention and control arms over 1 year. Results: The study included 4593 patients with previously diagnosed AF (2250 intervention; 2343 control). In the intervention arm, 2022 (89.9%) completed rhythm assessment (median 2 visits with rhythm assessment) and 40.1% had ≥1 "Possible AF" result. Initiation of OAC was similar in the intervention (17.7%) and control (19.1%) arms but was influenced by the rhythm assessment result: higher with a "Possible AF" (26.1%; adjusted odds ratio [aOR] 1.62; 95% confidence interval [CI] 1.04-2.51), and lower with a "Normal" result (9.9%; aOR 0.45; 95% CI 0.29-0.71) compared to control. OAC discontinuation was similar in the intervention (6.3%) and control (7.2%) arms, with lower discontinuation with a "Possible AF" result (3.8%; aOR 0.51; 95% CI 0.32-0.81). Conclusions: Including patients with previously diagnosed AF in a point-of-care rhythm assessment strategy did not increase overall OAC use compared to the control arm. However, the rhythm assessment result influenced both initiation and discontinuation of OAC.

15.
medRxiv ; 2023 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-37609134

RESUMO

Introduction: Consumer wearable devices with health and wellness features are increasingly common and may enhance prevention and management of cardiovascular disease. However, the characteristics and attitudes of wearable device users versus non-users are poorly understood. Methods: Wearable Activity Tracking for Comprehensive Healthcare-Integrated Technology (WATCH-IT) was a prospective study of adults aged ≥18 years receiving longitudinal primary or ambulatory cardiovascular care at one of eleven hospitals within the Mass General Brigham multi-institutional healthcare system between January 2010-July 2021. We invited patients, including wearable users and non-users, to participate via an electronic patient portal. Participants were asked to complete a 20-question survey regarding perceptions and use of consumer wearable devices. Responses were linked to electronic health record data. Multivariable logistic regression was used to identify factors associated with device use. Results: Among 280,834 individuals receiving longitudinal primary or cardiovascular care, 65,842 did not have an active electronic portal or opted out of research contact. Of the 214,992 individuals sent a survey link, 11,121 responded (5.2%), comprising the WATCH-IT patient sample. Most respondents (55.8%) reported current use of a wearable device, and most non-users (95.3%) reported they would use a wearable device if provided at no cost. Although most users (70.2%) had not shared device data with their doctor previously, the majority believed it would be very (20.4%) or moderately (34.4%) important to share device-related health information with providers. In multivariable models, older age (odds ratio [OR] 0.80 per 10-year increase, 95% CI 0.77-0.82), male sex (0.87, 95% CI 0.80-0.95), and heart failure (0.75, 95% CI 0.63-0.89) were associated with lower odds of wearable device use, whereas higher median zip code income (1.08 per 1-quartile increase, 95% CI 1.04-1.12) and care in a cardiovascular medicine clinic (1.17, 95% CI 1.05-1.30) were associated with greater odds of device use. Nearly all respondents (98%) stated they would share device data with researchers studying health outcomes. Conclusions: Within an electronically assembled cohort of patients in primary and cardiovascular medicine clinics with linkage to detailed health records, wearable device use is common. Most users perceive value in wearable data. Our platform may enable future study of the relationships between wearable technology and resource utilization, clinical outcomes, and health disparities.

16.
Ann Intern Med ; 176(7): 975-982, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37399548

RESUMO

BACKGROUND: The performance of rapid antigen tests (Ag-RDTs) for screening asymptomatic and symptomatic persons for SARS-CoV-2 is not well established. OBJECTIVE: To evaluate the performance of Ag-RDTs for detection of SARS-CoV-2 among symptomatic and asymptomatic participants. DESIGN: This prospective cohort study enrolled participants between October 2021 and January 2022. Participants completed Ag-RDTs and reverse transcriptase polymerase chain reaction (RT-PCR) testing for SARS-CoV-2 every 48 hours for 15 days. SETTING: Participants were enrolled digitally throughout the mainland United States. They self-collected anterior nasal swabs for Ag-RDTs and RT-PCR testing. Nasal swabs for RT-PCR were shipped to a central laboratory, whereas Ag-RDTs were done at home. PARTICIPANTS: Of 7361 participants in the study, 5353 who were asymptomatic and negative for SARS-CoV-2 on study day 1 were eligible. In total, 154 participants had at least 1 positive RT-PCR result. MEASUREMENTS: The sensitivity of Ag-RDTs was measured on the basis of testing once (same-day), twice (after 48 hours), and thrice (after a total of 96 hours). The analysis was repeated for different days past index PCR positivity (DPIPPs) to approximate real-world scenarios where testing initiation may not always coincide with DPIPP 0. Results were stratified by symptom status. RESULTS: Among 154 participants who tested positive for SARS-CoV-2, 97 were asymptomatic and 57 had symptoms at infection onset. Serial testing with Ag-RDTs twice 48 hours apart resulted in an aggregated sensitivity of 93.4% (95% CI, 90.4% to 95.9%) among symptomatic participants on DPIPPs 0 to 6. When singleton positive results were excluded, the aggregated sensitivity on DPIPPs 0 to 6 for 2-time serial testing among asymptomatic participants was lower at 62.7% (CI, 57.0% to 70.5%), but it improved to 79.0% (CI, 70.1% to 87.4%) with testing 3 times at 48-hour intervals. LIMITATION: Participants tested every 48 hours; therefore, these data cannot support conclusions about serial testing intervals shorter than 48 hours. CONCLUSION: The performance of Ag-RDTs was optimized when asymptomatic participants tested 3 times at 48-hour intervals and when symptomatic participants tested 2 times separated by 48 hours. PRIMARY FUNDING SOURCE: National Institutes of Health RADx Tech program.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , Estudos Prospectivos , SARS-CoV-2 , Reação em Cadeia da Polimerase , Cognição , Sensibilidade e Especificidade
17.
JMIR Ment Health ; 10: e44529, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37450333

RESUMO

BACKGROUND: Few studies have examined the association between depressive symptom trajectories and physical activity collected by mobile health (mHealth) devices. OBJECTIVE: We aimed to investigate if antecedent depressive symptom trajectories predict subsequent physical activity among participants in the electronic Framingham Heart Study (eFHS). METHODS: We performed group-based multi-trajectory modeling to construct depressive symptom trajectory groups using both depressive symptoms (Center for Epidemiological Studies-Depression [CES-D] scores) and antidepressant medication use in eFHS participants who attended 3 Framingham Heart Study research exams over 14 years. At the third exam, eFHS participants were instructed to use a smartphone app for submitting physical activity index (PAI) surveys. In addition, they were provided with a study smartwatch to track their daily step counts. We performed linear mixed models to examine the association between depressive symptom trajectories and physical activity including app-based PAI and smartwatch-collected step counts over a 1-year follow-up adjusting for age, sex, wear hour, BMI, smoking status, and other health variables. RESULTS: We identified 3 depressive symptom trajectory groups from 722 eFHS participants (mean age 53, SD 8.5 years; n=432, 60% women). The low symptom group (n=570; mean follow-up 287, SD 109 days) consisted of participants with consistently low CES-D scores, and a small proportion reported antidepressant use. The moderate symptom group (n=71; mean follow-up 280, SD 118 days) included participants with intermediate CES-D scores, who showed the highest and increasing likelihood of reporting antidepressant use across 3 exams. The high symptom group (n=81; mean follow-up 252, SD 116 days) comprised participants with the highest CES-D scores, and the proportion of antidepressant use fell between the other 2 groups. Compared to the low symptom group, the high symptom group had decreased PAI (mean difference -1.09, 95% CI -2.16 to -0.01) and the moderate symptom group walked fewer daily steps (823 fewer, 95% CI -1421 to -226) during the 1-year follow-up. CONCLUSIONS: Antecedent depressive symptoms or antidepressant medication use was associated with lower subsequent physical activity collected by mHealth devices in eFHS. Future investigation of interventions to improve mood including via mHealth technologies to help promote people's daily physical activity is needed.

18.
Am Heart J ; 265: 92-103, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37451355

RESUMO

BACKGROUND: Screening for atrial fibrillation (AF) using consumer-based devices capable of producing a single lead electrocardiogram (1L ECG) is increasing. There are limited data on the accuracy of physician interpretation of these tracings. The goal of this study is to assess the sensitivity, specificity, confidence, and variability of cardiologist interpretation of point-of-care 1L ECGs. METHODS: Fifteen cardiologists reviewed point-of-care handheld 1L ECGs collected from patients aged 65 years or older enrolled in the VITAL-AF clinical trial [NCT035115057] who underwent cardiac rhythm assessments with a 1L ECG using an AliveCor KardiaMobile device. Random sampling of 1L ECGs for cardiologist review was stratified by the AliveCor algorithm interpretation. A 12L ECG performed on the same day for clinical purposes was used as the gold standard. Cardiologists each reviewed a common sample of 200 1L ECG tracings and completed a survey associated with each tracing. Cardiologists were blinded to both the AliveCor algorithm and same day 12L ECG interpretation. For each tracing, study cardiologists were asked to assess the rhythm (sinus rhythm, AF, unclassifiable), report their assessment of the quality of the tracing, and rate their confidence in rhythm interpretation. The outcomes included the sensitivity, specificity, variability, and confidence in physician interpretation. Variables associated with each measure were identified using multivariable regression. RESULTS: The average sensitivity for AF was 77.4% (range 50%-90.6%, standard deviation [SD]=11.4%) and the average specificity was 73.0% (range 41.3%-94.6%, SD = 15.4%). The mean variability was 30.8% (range 0%-76.2%, SD = 23.2%). The average reviewer confidence of 1L ECG rhythm assessment was 3.6 out of 5 (range 2.5-4.2, SD = 0.6). Patient and tracing factors associated with sensitivity, specificity, variability, and confidence were identified and included age, body mass index, and presence of artifact. CONCLUSION: Cardiologist interpretation of point-of-care handheld 1L ECGs has modest diagnostic sensitivity and specificity with substantial variability for AF classification despite high confidence. Variability in cardiologist interpretation of 1L ECGs highlights the importance of confirmatory testing for diagnosing AF.

19.
Cardiol Cardiovasc Med ; 7(2): 97-107, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37476150

RESUMO

Wrist-based wearables have been FDA approved for AF detection. However, the health behavior impact of false AF alerts from wearables on older patients at high risk for AF are not known. In this work, we analyzed data from the Pulsewatch (NCT03761394) study, which randomized patients (≥50 years) with history of stroke or transient ischemic attack to wear a patch monitor and a smartwatch linked to a smartphone running the Pulsewatch application vs to only the cardiac patch monitor over 14 days. At baseline and 14 days, participants completed validated instruments to assess for anxiety, patient activation, perceived mental and physical health, chronic symptom management self-efficacy, and medicine adherence. We employed linear regression to examine associations between false AF alerts with change in patient-reported outcomes. Receipt of false AF alerts was related to a dose-dependent decline in self-perceived physical health and levels of disease self-management. We developed a novel convolutional denoising autoencoder (CDA) to remove motion and noise artifacts in photoplethysmography (PPG) segments to optimize AF detection, which substantially reduced the number of false alerts. A promising approach to avoid negative impact of false alerts is to employ artificial intelligence driven algorithms to improve accuracy.

20.
J Clin Transl Sci ; 7(1): e120, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37313378

RESUMO

Background: Rapid antigen detection tests (Ag-RDT) for SARS-CoV-2 with emergency use authorization generally include a condition of authorization to evaluate the test's performance in asymptomatic individuals when used serially. We aim to describe a novel study design that was used to generate regulatory-quality data to evaluate the serial use of Ag-RDT in detecting SARS-CoV-2 virus among asymptomatic individuals. Methods: This prospective cohort study used a siteless, digital approach to assess longitudinal performance of Ag-RDT. Individuals over 2 years old from across the USA with no reported COVID-19 symptoms in the 14 days prior to study enrollment were eligible to enroll in this study. Participants throughout the mainland USA were enrolled through a digital platform between October 18, 2021 and February 15, 2022. Participants were asked to test using Ag-RDT and molecular comparators every 48 hours for 15 days. Enrollment demographics, geographic distribution, and SARS-CoV-2 infection rates are reported. Key Results: A total of 7361 participants enrolled in the study, and 492 participants tested positive for SARS-CoV-2, including 154 who were asymptomatic and tested negative to start the study. This exceeded the initial enrollment goals of 60 positive participants. We enrolled participants from 44 US states, and geographic distribution of participants shifted in accordance with the changing COVID-19 prevalence nationwide. Conclusions: The digital site-less approach employed in the "Test Us At Home" study enabled rapid, efficient, and rigorous evaluation of rapid diagnostics for COVID-19 and can be adapted across research disciplines to optimize study enrollment and accessibility.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...